Kramer-electronics VS-66HN User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
VS-66HN - Protocol 3000
11 Protocol 3000
By default, the VS-66HN is set to Protocol 2000 (see Section 10) but is also
compatible with Kramer’s protocol 3000.
Note that the VS-66HN needs to be set to protocol 2000 in order to
use the IR remote control.
The VS-66HN can be operated using serial commands from a PC, remote
controller or touch screen using the Kramer Protocol 3000.
This section describes:
Kramer Protocol 3000 syntax (see Section 11.1)
Kramer Protocol 3000 commands (see Section 11.2)
11.1 Kramer Protocol 3000 Syntax
11.1.1 Host Message Format
Start
Address (optional)
Body
Delimiter
#
device_id@
Message
CR
11.1.1.1 Simple Command
Command string with only one command without addressing:
Start
Body
Delimiter
#
Command SP Parameter_1,Parameter_2,…
CR
11.1.1.2 Command String
Formal syntax with commands concatenation and addressing:
Start
Address
Body
Delimiter
#
device_id@
Command_1 Parameter1_1,Parameter1_2,…|
Command_2 Parameter2_1,Parameter2_2,…|
Command_3 Parameter3_1,Parameter3_2,…|…
CR
11.1.2 Device Message Format
Start
Address (optional)
Body
delimiter
~
Sender_id@
Message
CR LF
i