Connecting the RGBHV/Balanced Audio Matrix Switcher
17
17
Table 3: DIP-switch Settings
# DIP-switch Number Function
1 1 RS-485 Termination
2 2, 3, 4 Not used
3 5, 6, 7, 8 Machine number (see Table 4)
DIP-switch 1 determines the RS-485 bus termination for the VP-88K. Moving the
switch up turns the termination off (default), moving the switch down turns the
termination on.
DIP-switches 2, 3, and 4 are not used.
DIP-switches 5, 6, 7, and 8 determine the machine number of the VP-88K. When
several VP-88K units are connected, the machine number determines the unique
identity of the VP-88K in the sequence (see
Table 4).
When using a stand-alone VP-88K unit, set the machine number to 1 (factory
default)
When connecting more than one VP-88K, set the first machine (connected via
RS-232) to be machine number 1. The other VP-88K units must each be set to
a unique machine number between 2 and 16.
Table 4: Machine Number DIP-switch Settings
Machine Number
DIP-switch
Machine Number
DIP-switch
5 6 7 8
5 6 7 8
1
(Master, default)
OFF OFF OFF OFF
9 (Slave) ON OFF OFF OFF
2 (Slave) OFF OFF OFF ON
10 (Slave) ON OFF OFF ON
3 (Slave) OFF OFF
ON OFF
11 (Slave) ON OFF ON OFF
4 (Slave) OFF OFF ON ON
12 (Slave) ON OFF ON ON
5 (Slave) OFF ON OFF OFF
13 (Slave) ON ON OFF OFF
6 (Slave) OFF ON OFF
ON
14 (Slave) ON ON OFF ON
7 (Slave) OFF ON ON OFF
15 (Slave) ON ON ON OFF
8 (Slave) OFF ON ON ON
16 (Slave) ON ON ON ON